Tips for Creating a Properties Verification Reason for Rational Functional Tester : RFT?

0 37

Brief Introduction: How a Properties Verification Level operate:

The purpose of a Qualities verification point is to test your object’s properties in our application.

Each time a verification point is saved, a baseline of the object’s qualities gets created. After that, whenever the script is played back, the properties will probably be compared to confirm if virtually any changes have occurred, possibly intentionally or even unintentionally.

With the aid of the Properties verification point, we could identify the presence of potential flaws in our application.

This article gifts a simple method of creating a Qualities Verification Point in RFT regarding testing the properties of your object.

Steps to create a Qualities Verification Point are seeing that under:

Step – just one: Starting the recording surgery of script:

a) To get RFT – Java Coding: Click the “Record a Functional Battery tester Script” button on the RFT toolbar or the “File” > “New” > “Functional Tester Script Employing Recorder” menu command.

b) For RFT – VB. NET Scripting: Click the “Record a Functional Tester Script” option on the RFT toolbar, possibly the “File” > “New” > “Add Screenplay Using Recorder” menu command line.

Step – 2: Inside RFT Recording Monitor, click on the “Start Application” button to start with the test application.

Step instructions 3: Locate the object inside the application we want to test.

Step – 4: Inside the Functional Tester Recording Display, click the “Insert Verification Position or Action Command” option on the toolbar.

Step instructions 5: Picking up the object inside the application:

The objects in the application can be picked up for the “Select an Object page” with the Verification Point and Steps wizard with the following three selection procedures.

Method 1: Object Person Tool method: For selecting an item and all descendants of the target, select one object and an object and the speedy children of an object.

Procedure 2: Test Object Cell phone browser method: For browsing for the goal we want to select. Often the browser displays a hierarchical tree of objects in the application. The top level indicates any applications we are managing. Under each top amount, RFT displays the object power structure within that application. It can be a dynamic view of you can buy objects.

Method 3: Time frame Delayed method: For selecting pop-up objects, like menus. This approach uses the Object Finder program but enables us to set a new delay, which gives us a chance to reach an object which involves clicking on other objects initially.

Step – 6: Growth to the next page in the Confirmation Point and Action magician:

On the Select an Object webpage, the check box “After picking an object advance to subsequent page” is selected automatically. This causes automatic improvement to the next page in the Confirmation Point and Action magician.

Alternatively, If the check box “After selecting an object advance to be able to next page” is deselected, we need to manually click “Next” to move to the next page.

Phase – 7: Selection of choices for properties verification level:

a) On the “Select a great Action” page, click the “Perform Properties Verification Point” alternative, and then click “Next”.

b) Use either of the next four options:

1) “Include Children” – In the event, we want to include the properties in the object’s child objects (in case it has child objects).

2) ” non-e inches – For testing the item only without children.

3) “Immediate” – For tests, the object and any quick children present at one particular level down)

4) “All” – For testing the item, including all of its youngsters down the entire hierarchy.

Phase – 8: Providing a good name to the Verification Level:

Under “Verification Point Name”, accept the suggested standard, or type a new label in the box. The new label, if any, must be before standard Java naming promotions.

Step – 9: Variety of properties type: Choose if to use the standard and non-standard properties types.

Typical properties are available across tools and browsers, whereas non-standard properties can include platform-specific houses.

Step – 10: Setting up of retry time for often the verification point during the record:

The retry option is effective when playback does not choose the verification point in the application, along with the retry option checking the presence of the verification point.

a) We often use the “Include Retry Parameters” to set the retry time for the proof point during playback. We can either use the default principles or set our principles for the “Maximum Retry Time” & “Retry Interval”.

Following, by default RFT will check out the existence of the verification stage of the application every two just a few seconds, for up to 20 seconds.

b) The value set under “Maximum Retry Time” indicates the absolute maximum number of seconds RFT will probably retry for the verification examination appearing in the application during the record.

c) The value set within “Retry Interval” indicates how many seconds between times this RFT will check for often the verification point during the waiting period.

d) Click “Finish” to write the retry to get a verification point into the screenplay, which will take place on long-term playbacks.

Step – 10: Editing the properties info: (Optional step)

We need certainly not test each & every single property of the test subject every time. Hence it is better to be able to test the specific set of qualities we want while using a Qualities verification point.

a) Quality object’s properties and ideals are available for editing in a forest table format on the “Verification Point Data” page.

b) Only those properties may be edited which happened to be analyzed. We can edit the qualities in the “Property” column and will edit the property values inside the “Value” column.

c) Choosing one of the object properties simply by check marking them for that test:

– By default, just about all properties appear with no checkmark, meaning they will not end up being tested.

– We need to utilize the check mark against the selected properties desired to be tested.

– Check designated properties will be tested every time we play back any script with this verification level.

– We can select just about all properties in the list simply by clicking the “Check All” toolbar button above the main grid.

– We can use the “Uncheck All” button to clear selecting all the properties.

– To be able to edit a value, double-click the particular tree table cell. That specific cell becomes editable. We can easily click outside the cell, which may cause the edit to take the outcome. Read also: https://www.lmcrs.com/category/real-estate/

Leave A Reply